Q-equation, threshold energy, cross-sections, level width, Breit-Wigner formula
- UP GDC Mains
4 minute read · Updated 2026-11-15
Picking up from
In Nuclear reactions, mechanisms, compound nuclei and direct reactions, we saw that direct reactions transfer particles or momentum promptly, while compound reactions redistribute excitation before the intermediate nucleus decays. Why does a negative reaction energy require extra laboratory input, and what sets a resonance width?
In one line
Reaction thresholds follow energy–momentum conservation, while resonance widths encode finite-lived intermediate states and channel-dependent cross sections.
The idea, explained
An endoergic reaction needs more incident laboratory kinetic energy than the magnitude of its negative reaction energy because final products must also carry momentum. A stationary target does not make the total momentum zero. Center-of-mass energy or an invariant total energy therefore gives the cleanest threshold condition.
A compound or scattering resonance enhances a reaction near an intermediate energy. Its finite lifetime corresponds to an energy width, and its decay into different channels is represented by partial widths. An isolated Breit–Wigner form organizes the resulting line shape, but neighboring resonances, background interference and energy-dependent channels can change it. A resonance peak is not an arbitrary divergent cross section: angular factors, entrance wavelength and total width constrain its magnitude. Width, energy resolution and observed profile must also be kept distinct. A threshold opening and a resonance peak can lie near each other yet have different physical origins and mathematical behavior.
Core ideas
- The laboratory threshold depends on projectile and target masses because momentum conservation reserves some input energy for overall motion.
- Exoergic reactions have no positive kinematic threshold from rest-mass deficit, but barriers or selection rules can still suppress their rates.
- The total resonance width is the sum of partial decay widths in the model; branching fractions are partial width divided by total width.
- A narrow width corresponds to a longer intermediate lifetime, subject to the energy–time Fourier convention and the isolated exponential-decay model.
- A measured peak includes beam spread and detector resolution. Its observed full width need not equal the intrinsic nuclear width without a response analysis.
Key formulas
Exact stationary-target threshold
This two-body endoergic threshold assumes target at rest and final products at minimal invariant mass.
Isolated resonance and lifetime
is the stated spin statistical factor, entrance relative wave number and total energy width; a noninterfering isolated resonance is assumed.
Choose a mass convention and identify whether the threshold formula assumes two final bodies. Use invariant energy for relativistic or multi-particle thresholds rather than adding an unexplained recoil correction. In a resonance calculation, distinguish entrance, exit and total widths and state the spin factor. Check whether the energy is laboratory or center-of-mass and whether width parameters use the same variable. Do not apply one isolated Lorentzian across overlapping levels or a nearby rapidly changing threshold without acknowledging the approximation.
Quick worked example
For a narrow resonance with a fixed total width, its lifetime is . Halving the intrinsic energy width doubles that lifetime. A broader instrument response can hide this change unless it is accounted for in fitting.
Where this leads
Continue to Rutherford scattering, because Rutherford scattering provides a useful nonresonant cross-section benchmark.
Related: Nuclear reactions, mechanisms, compound nuclei and direct reactions — prerequisite definitions used in this model.
Practice this topic
Practice this topic25 questions in Assistant Professor · Physics · Physics. Sign in and practice access may be required.