2-probe and 4-probe resistance measurement, design of DC power supply
- GATE
4 minute read · Updated 2026-11-15
Picking up from
In Filtering, noise reduction, shielding and grounding, we saw that active filters combine frequency-selective networks with amplification or buffering to control passbands, attenuation and loading. How do leads, contacts and supply behavior affect an apparently simple resistance measurement?
In one line
Four-terminal sensing separates current delivery from voltage measurement, while a dc supply requires controlled conversion, filtering and regulation.
The idea, explained
A two-terminal resistance measurement includes lead and contact voltage drops along the same path carrying test current. This can dominate a low-resistance specimen. Four-terminal sensing uses one pair to force current and another high-impedance pair to measure sample voltage, reducing the contribution from voltage-lead and contact resistance under the stated geometry.
The separation does not remove every error: finite input current, thermoelectric offsets, nonuniform current paths and sample heating can remain. Converting measured resistance into resistivity also requires sample dimensions or a valid geometry factor. A dc power supply commonly combines rectification, energy storage and regulation. Ripple depends on load and filtering, while regulation requires headroom and thermal limits. Measurement and supply design meet when the source current or voltage used for a test changes the sample or injects noise into the readout.
Core ideas
- Four-wire sensing reduces certain series drops but does not automatically eliminate contact-related changes of sample current distribution.
- Use a sufficiently high-impedance voltage readout and check its input bias. Infinite impedance is an idealization, not a property inferred from the number of wires.
- Reverse current or suitable averaging can help separate odd-in-current resistive voltage from approximately fixed thermal offsets, subject to drift and settling.
- A filter capacitor stores charge between rectifier charging intervals. Its ripple estimate depends on ripple frequency and load, not solely on mains frequency as an unlabeled number.
- A regulator needs adequate input headroom and dissipates power. A constant nominal output voltage does not imply unlimited current or zero heat.
Key formulas
Four-terminal resistance and uniform-bar resistivity
The resistivity relation assumes a uniform bar with cross-section and voltage-probe spacing .
Capacitor ripple and linear-regulator heating
The ripple estimate assumes approximately constant load and small discharge between recharge events; the regulator estimate neglects quiescent and other losses.
Choose current and geometry to keep self-heating and contact effects controlled. Separate force and sense connections at the relevant sample locations and state the voltage-probe impedance model. Include offsets and reversal timing in uncertainty estimates. For a supply, draw rectifier, filter and regulator stages, calculate the lowest input trough under load, and check headroom and dissipation. Do not replace protective circuitry or device ratings with a simplified ripple equation; use supplied component constraints for any implementation-specific conclusion.
Quick worked example
A low-resistance sample is measured with current reversal. The half-difference isolates the resistive contribution if the offset remains fixed. Its validity must be checked if heating or drift changes between readings.
Where this leads
Continue to Fourier transforms, lock-in detector, box-car integrator, modulation techniques, because synchronous techniques can recover weak signals at a chosen modulation frequency.
Related: Filtering, noise reduction, shielding and grounding — prerequisite definitions used in this model.
Practice this topic
Practice this topic4 questions in Assistant Professor · Physics · Physics. Sign in and practice access may be required.