PhysicsScore

Langevin and quantum theories, magnons, hysteresis

  • UP GDC Mains

4 minute read · Updated 2026-11-15

Picking up from

In Dia-, para-, ferro-, antiferro- and ferrimagnetism, ferromagnetic domains, we saw that Magnetization describes material magnetic moments, separating free-current sources from the bound currents associated with matter. Which microscopic models distinguish classical orientation from quantum spin response?

In one line

Classical orientations, quantum spin populations and collective magnons describe different limits of magnetic response and temperature dependence.

The idea, explained

Magnetization is magnetic dipole moment per unit volume. Microscopic current loops and intrinsic magnetic moments can produce an averaged magnetic response even when no macroscopic free current crosses the material. The auxiliary magnetic field separates the magnetization contribution from magnetic induction, allowing a magnetostatic circulation law written in terms of free current.

For a linear isotropic material, magnetization is proportional to the auxiliary field through magnetic susceptibility. Diamagnetic response weakly opposes the applied field, while paramagnetic response weakly reinforces it under the simple equilibrium model. Ferromagnets can show spontaneous magnetization, domains and hysteresis, so a single constant susceptibility is generally inadequate. The distinction between induction and auxiliary field matters at material boundaries: one has a normal continuity law, while the other's tangential jump is controlled by free surface current. Later interface equations make those boundary statements precise rather than replacing them with one universal permeability rule.

Core ideas

  • Bound magnetization currents represent material response, while free currents are specified separately. Both can contribute to the physical magnetic induction.
  • Uniform magnetization can have zero volume bound current but nonzero surface bound current. Ignoring the surface term misses the field of many uniformly magnetized bodies.
  • Susceptibility and relative permeability are related simply only in the assumed linear isotropic constitutive model. Direction-dependent or hysteretic media require a tensor or history-dependent response.
  • A ferromagnetic hysteresis loop means the state depends on preparation. The induction is not then a unique single-valued linear function of the applied auxiliary field.
  • Demagnetizing fields depend on sample geometry, so the internal field can differ from the externally applied field. A quoted bulk susceptibility alone does not solve a finite sample problem.

Key formulas

Magnetization and auxiliary magnetic field

B=μ0(H+M),jb=∇×M,Kb=M×n^\mathbf B=\mu_0(\mathbf H+\mathbf M),\qquad\mathbf j_b=\nabla\times\mathbf M,\quad\mathbf K_b=\mathbf M\times\hat{\mathbf n}

M\mathbf M is magnetization; jb\mathbf j_b and Kb\mathbf K_b are volume and surface bound currents.

Curie susceptibility and Curie–Weiss approximation

χ=μ0nμeff23kBT,χCW=CT−Θ\chi=\frac{\mu_0n\mu_{\mathrm{eff}}^2}{3k_{\mathrm B}T},\qquad\chi_{\mathrm{CW}}=\frac{C}{T-\Theta}

The Curie expression assumes weak-field independent moments with the stated effective moment. The Curie–Weiss form is a mean-field response above its ordering regime; it is not a universal low-temperature ferromagnet law. Ordinary diamagnetism does not generally follow this inverse-temperature form.

Linear isotropic magnetic response

M=χmH,B=μH,μ=μ0(1+χm)\mathbf M=\chi_m\mathbf H,\qquad\mathbf B=\mu\mathbf H,\qquad\mu=\mu_0(1+\chi_m)

The susceptibility χm\chi_m is constant in this model; nonlinear and hysteretic materials require a different constitutive description.

Identify whether the given magnetic field means induction, auxiliary field or externally applied field. State the constitutive assumption before converting between them. Include bound surface currents when using a magnetization description, or use the auxiliary-field equation with free currents consistently. For a finite specimen, determine the internal-field relation from geometry rather than treating a long-solenoid approximation as universal. Check units: magnetization and auxiliary field share current-per-length units, while magnetic induction is measured in tesla.

Ferromagnetic spin-wave scale

ℏωk≃Dk2\hbar\omega_{\mathbf k}\simeq Dk^2

A simple isotropic ferromagnet has quadratic long-wavelength magnons, quanta of collective spin waves, with stiffness DD. Anisotropy and fields can open a gap; antiferromagnetic modes need a different model. Langevin response treats classical orientations, while Brillouin response counts discrete spin projections. Hysteresis also involves domains and history, not equilibrium susceptibility alone.

Quick worked example

For a linear material with χm=0.02\chi_m=0.02 and known internal H=100 A m−1H=100\,\mathrm{A\,m^{-1}}, the magnetization is M=2 A m−1M=2\,\mathrm{A\,m^{-1}}. The induction is B=102μ0B=102\mu_0 in tesla; the internal field must be known, not replaced automatically by the applied field.

Where this leads

Continue to Dielectric properties, polarizability, ferroelectricity, because electric polarization provides a parallel but distinct kind of material order.

Related: Dia-, para-, ferro-, antiferro- and ferrimagnetism, ferromagnetic domains — prerequisite definitions used in this model.